Fluke 117C Digital Multimeter, Non-Contact AC Voltage Detection, Measures Resistance/Continuity/Frequency/Capacitance/Min Max Average, Automatic AC/DC Voltage Selection, Low Impedance Mode
The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117 includes integrated non-contact voltage detection to help get the job done faster.
VoltAlert technology for non-contact voltage detection
AutoVolt automatic AC/DC voltage selection. DC millivolts – Range:600.0 mV, Resolution:0.1 mV
Low input impedance:helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
True RMS for accurate measurements on non-linear loads.Operating temperature:-10?FC to +50?FC.Battery life:400 hours typical, without backlight
AutoVolt automatic ac/dc voltage selection
LoZ:Helps prevent false readings due to ghost voltage
True-rms for accurate measurements on non-linear loadsMeasures 10 A (20 A overload for 30 seconds)Resistance, continuity, frequency and capacitanceMin/Max/Average to record signal fluctuationsCompatible with optional magnetic hanger (ToolPak) for hands free operationCAT III 600 V safety rate
Brand | Fluke 117C |
Mode | Fluke 117C |
Power Source | AAA batteries required. (Not included) |
Style | Multimeter Standard |
Item Weight | 550 Grams |
Item Dimensions LxWxH | 6.57 x 3.31 x 1.81 inches |
Measurement Type | Multimeter |
Measurement Accuracy | /-0.5% |
Specifications:
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Fuse for A input 11 A, 1000 V FAST Fuse (PN 803293)
Display Digital:6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10 ?FC to + 50 ?FC
Storage temperature -40 ?FC to + 60 ?FC
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life 400 hours typical, without backlight
Accuracy Specifications
DC millivolts Range/Resolution 600.0 mV / 0.1 mV
Accuracy ?? ([% of reading] + [counts]):0.5% + 2
DC volts Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ?? ([% of reading] + [counts]):0.5% + 2
Auto volts Range/Resolution 600.0 V / 0.1 V
Accuracy 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms Range/Resolution 600.0 mV / 0.1 mV
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity Range/Resolution 600 ?? / 1 ??
Accuracy Beeper on < 20 ??, off > 250 ??; detects opens or shorts of
500 ?Ss or longer
Ohms Range/Resolution 600.0 ?? / 0.1 ??
6.000 k?? / 0.001 k??
60.00 k?? / 0.01 k??
600.0 k?? / 0.1 k??
6.000 M?? / 0.001 M??
Accuracy 0.9 % + 1
Range/Resolution 40.00 M?? / 0.01 M??
Accuracy 5 % + 2
Diode test Range/Resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance Range/Resolution 1000 nF / 1 nF
10.00 ?SF / 0.01 ?SF
100.0 ?SF / 0.1 ?SF
9999 ?SF / 1 ?SF
100 ?SF to 1000 ?SF
Accuracy 1.9% + 2
Range/Resolution > 1000 ?SF
Accuracy 5% + 20%
Lo-Z capacitance Range 1 nF to 500 ?SF
Accuracy 10% + 2 typical
AC amps true-rms (45 Hz to 500 Hz) Range/Resolution 6.000 A / 0.1 A
10.00 A / 0.01 A
Accuracy 1.5% + 3
20 A continuous overload for 30 seconds max
DC amps Range/Resolution 6.000 A / 0.1 A10.00 A / 0.01 A
Accuracy 1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)2 Range/Resolution 99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2
Additional information
Weight | 0.623 kg |
---|