Sale!

ANCEL AC3000 Manifold Digital Meter Air Conditioner Refrigerant Leak Tester Fault Check Vacuum Temperature Tester

SKU: HA1937731

Original price was: $310.26.Current price is: $277.02.

-11%
Shipping fast worldwide
  • Dispatch:Usually will be shipped in 24 hours
  • Shipping Time:Expedited Express 6-8 business days
  • Secure Payment:Paypal,VISA,MasterCard
Guaranteed Safe Checkouttrust pay
ANCEL AC3000 Manifold Digital Meter Air Conditioner Refrigerant Leak Tester Fault Check Vacuum Temperature Tester
$310.26 Original price was: $310.26.$277.02Current price is: $277.02.

ANCEL AC3000 Manifold Digital Meter Air Conditioner Refrigerant Leak Tester Fault Check Vacuum Temperature Tester
Description:
ANCEL AC3000 digital manifold is a professional instrument for installation, testing and maintenance of refrigeration equipment such as air conditioners and cold stores. It combines 2-way pressure test, dual temperature measurements ( with optional dual temperature probes ), a 32-bit digital processor and a large LCD in one easy-to-use instrument with the following main functions.
1.Pressure and Saturation Temperature
2.Vacuum Operation
3.Pressure Leak Test with recording
4.Direct T1 T2 Temperature, Real-time Super heat and Sub cooling Simultaneously Display with Optional Two Clamp-on Temperature Probes
5.89 Refrigerant Profiles Stored in The Instrument
6.Automatic Multi-unit Pressure Conversion
7.Automatic Temperature ??/?H Conversion
It is the right one you have to do the job right.
Pressure Measuring
1. Turn off the blue valve and red valve.
2. Turn on the instrument. Then verify that LCD displays the status of the pressure test.If not,press the function button to switch it.
3. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. At this time, press the zero button long until it returns to zero.
4. Press R+/ R- buttons , Unit button and ??/?H button to select tested refrigerant and reading display respectively.
5. If the clamp-on temperature probes have been connected to the instrument, the real-time temperature will be displayed.If not, no display of it.
6. Connect the instrument to the refrigeration system according to the chart below.
7. Turn on the refrigerant valve and gently press the pressure release valve to vent the air in the connecting hose.
8. When the refrigeration system stops, turn on the high pressure valve (red valve) and fill with a certain amount of refrigerant and then shut the valve quickly.
9. Run the refrigeration system, turn on the low pressure valve (blue valve), and fill with the refrigerant into the refrigeration system.
10. After the filling is completed, shut the low pressure valve (blue valve) and refrigerant valve. Let the refrigeration system running.
11. Shut down the refrigeration system,make sure all valves are turned off , then disconnect the instrument between refrigeration system and source. Do not remove the high pressure valve connection until the pressure drops to the safe point. Then turn off the instrument.
Vacuum Operation:
1. Turn off the blue valve and red valve.
2. Power on the instrument. Then make sure the LCD displays vacuum test status.If not, press the Function button to switch it.
3. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. At this time, press the zero button long until it returns to zero
4. Press the unit button to adjust the reading unit.
5. Connect the instrument to the refrigeration system.(Connected clamp-on temperature probes will not affect the operation.)
6. Turn on the blue valve and red valve, and start the vacuum pump.
7. After the vacuum operation is completed,turn off the blue valve and red valve, then shut the vacuum pump. At this time,pressure leak test mode can be used to check leakage in the system ( Please refer to Pressure Leak Test).
Pressure Leak Test
1. The instrument is powered on with the blue and red valves turned off.
2. Press the Function button to pressure leak test mode.The current pressure value is displayed at lower rightcorner of LCD.
3.Press the Run/Stop button to start the leak test
At this time, the lower left corner records the initial pressure value; the lower right corner displays the instantaneous pressure value; the ‘P’ display area shows the difference between the initial pressure value and the instantaneous pressure value.
The time display shows how long the leak test will take, in hour:minute (HH:MM)format. All pressure units on the screen are the same. You can switch between the different pressure units by pressing the Unit button.
Specifications:

Pressure test gauge pressure
Pressure test unit Kpa; Mpa; bar; inHg; PSI.
Pressure test range 0 Kpa ?C 6000 Kpa
Pressure test resolution 1 Kpa
Pressure test accuracy +/- 0.5 %(FS)+ 5dgt
Pressure overload limit 10000 Kpa (10 Mpa; 100 bar;)
Vacuum test relative vacuum
Vacuum test unit Kpa; Mpa; bar; inHg; PSI.
Vacuum test range -101 Kpa ?C 0 Kpa
Vacuum test resolution 1 Kpa
Temperature test unit ??C (Celsius), ??F (Fahrenheit)
Temperature test range -40??C?C150??C (-40??F?C302??F)
Temperature test resolution 0.1??C (-40??C?C99.9??C), 1??C (100??C?C150??C) 0.1??F (-40??F?C99.9??F), 1??F (100??F?C302??F)

Additional information

Weight 3.075 kg

Reviews

Write review “ANCEL AC3000 Manifold Digital Meter Air Conditioner Refrigerant Leak Tester Fault Check Vacuum Temperature Tester”

Your email address will not be published. Required fields are marked *

Shipping Methods


Payment Methods

[contact-form-7 id="230e2c7" title="Wholesale Inquiry"]
Free Worldwide Shipping

On all orders above $50

Easy 30 days returns

30 days money back guarantee

International Warranty

Offered in the country of usage

100% Secure Checkout

PayPal / MasterCard / Visa

payment

Copyright © 2023 hobbyant.com All Rights Reserved.